Fault Finding

The following alarms are reported at a connected ASL Router.
Table 1
VIPET Alarms on ASL Router
Fault Code Reported and Logged
VPT: LAN <nn>
nn=0 is VIPET LAN port ETH0
nn=1 is VIPET LAN port ETH1
VPT: DVA <n>
n=number of the VIPET DVA
VPT: FAULT 01
VPT: FAULT 02
VPT: FAULT 03
VPT: FAULT 04
VPT: CPU RESET
VPT: BMB<nn> COM
nn=Remote I/O unit address
VPT: BMB<nn> AIN xx
nn=Remote I/O unit address
xx=Analogue input channel number
VPT: BMB<nn> DOUT xx
nn=Remote I/O unit address
xx=Digital output channel number
VPT: IP<nn> AUD
nn=number of VIPET input
VPT: IP<n> CAP
nn=number of VIPET input
VPT: IP<n> COM
nn=number of VIPET input
VIPET - Hardware Installation and Maintenance Guide
Description
LAN fault
DVA fault
DC1 power supply fault. Only
for VIPET-PSU-24V.
DC2 power supply fault. Only
for VIPET-PSU-24V.
Over
temperature.
temperature inside the unit
exceeds 55°C.
USB fault. System will reboot.
CPU rebooted due to:
watchdog fault
communication
between VIPET and ASL
Router (> 15 seconds)
Communication
between VIPET and Remote I/O
Expander unit (BMB01)
Remote
I/O
channel fault
Remote I/O unit digital output
channel fault
Audio input surveillance fault
Microphone capsule fault
Communication
between
VIPET
microphone
U-0582-0512.doc – Issue: 05 complete, approved
Page 17 of 24
Check the network cabling.
Check the DC1 power supply.
Check the DC2 power supply.
The
Check the ambient temperature in the
equipment room.
Clear the alarm by pressing the ASL Router
"FAULT CLEAR" button.
Check if VIPET "SYSTEM FAULT" LED still
failure
indicates a fault.
If
the
communication between VIPET and ASL
Router.
If there is no communication failure, report
the fault to ASL.
failure
Check the cabling to the Remote I/O unit.
Check the RS485 termination.
Check that the address of the Remote I/O
unit is correct.
If all above is OK, check the unit's internal
CPU and COMMS LED.
unit
analogue
Check the wiring of volume control or
selector on the specified analogue channel.
Check the load connection on the specified
digital channel.
Check the audio and power supply cabling
between the microphone and VIPET.
Check continuity of microphone capsule or
any associated wiring.
failure
Check the data and power supply cabling
and
between the microphone and VIPET.
Suggested Action
fault
still
exists,
check
the

Hide quick links: