Disassembly and Reassembly > Disassembly
(16) LCD Unit
1) Disconnect the fl at cable from EXL circuit board (a).
2) Remove the two screws [E], taking care not to lose the LCD ground plate (b), which will be de-
tached at this time.
Note:
Take great care when handling the LCD unit.
The LCD unit has an LCD panel that is a precision component: Subjecting it to any impact could
result in a fault.
(a) EXL circuit board
(b) LCD ground plate
(c) LCD unit
(d) L case
Fig. 5-3-16
5 - 19