Removal Procedure
Steps
4. Remove swing assy
Remove 2 screws fixing swing assy, pull
out the connection wires with electric box,
and then pull the swing assy outwards
to remove it.
5. Remove water tray assy
Remove 2 screws fixing water tray, and
then pull the water tray outwards to
remove it.
6. Remove electric box assy
Remove one screw fixing electric box assy,
pull out all connection wire, and then pull
the electric box assy outwards to remove it.
Procedure
swing assy
screw
screw
water tray assy
electric box assy