Part10 Removal Procedure; Removal Procedure Of Indoor Unit - Vivax ACP-12CT35GECI Service Manual

Table of Contents

Advertisement

10. Removal Procedure

10.1 Removal Procedure of Indoor Unit

Steps
1. Remove panel
Pull the slide clasps at both sides of
panel, pull the panel outwards, lift up the
panel and then remove the panel.
2. Remove filter
Loosen the clasp on the upper side of
filter, pull the panel outwards to remove
it.
3. Remove front case
Remove the 4 screws fixing front case;
Disengage the clasps on both sides
(Follow the arrows); pull the front
case outwards, and then remove
the front case.
48
Warning
Be sure to wait for a minimum of 10 minutes after
turning off all power supplies before disassembly.
Procedure
panel
filter
front case
Removal Procedure
slide clasps
screw