SLEEP:
9
Press this button, can select Sleep 1 (
circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main
unit setting temperature will increase 1
setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will
decrease 1
, 2 hours, setting temperature will decrease 2 , then the unit will run at this setting
temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
Sleep 3- the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep
setting status, at this time, the time of remote control will display "1hour ", the setting temperature "88" will
display the corresponding temperature of last setting sleep curve and blink (The first entering will display
according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press
"Trubo "button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote control, (that are
"2hours " or "3hours " or "8hours "), the place of setting temperature "88" will display the
corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)
curve setting finished, at this time, the remote control will resume the original timer display;
temperature display will resume to original setting temperature.
Sleep3- the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user
individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the
sleep curve setting within10s, there is no button pressed, the sleep curve setting status will be automatically
quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF"
button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
10
TEMP:
Pressing TEMP button,
(outdoor ambient temperatur) and blank is displayed circularly .The unit defaults not to
display the icon. During operation of TEMP button, the set temperature is always displayed.
Note: Outdoor ambient temperature is only displayed for some models.
QUIET:
11
Press this button, the Quiet status is under the Auto Quiet mode (display "
and Quiet mode (display "
after powered on, the Quiet OFF is defaulted. Note: the Quiet function cannot be set up in Fan
and Dry mode;Under the Quiet mode (Display "
signal), the fan speed is not available.
12
CLOCK :
Press CLOCK button, blinking
present time.Holding down either button above 2 seconds increases or decreases the
time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During
blinking after setting, press CLOCK button again to confirm the setting,and then
will be constantly displayed.
T-ON T-OFF:
13
Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply
press this button again.
After press of this button,
setting. Within 5 seconds, press + or - button to adjust the time value. Every press of either
button changes the time setting by 1 minute. Holding down either button rapidly changes the
time setting by 1 minute and then 10 minutes. Within 5 Seconds after setting, press TIMER
ON button to confirm.
Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply
press the button again.TIMER OFF setting is the same as TIMER ON.
20
), Sleep 2 (
,setting temperature increased 2 , the unit will run at this
(3) operation, until 8hours temperature setting finished, sleep
(set temperature),
(indoor ambient temperature) and
" singal) and Quiet OFF (there is no signal of "
" Under the Quiet mode (Display "
. Within 5 seconds,pressing +or - button adjusts the
disappears and "ON "blinks .00:00 is displayed for ON time
),Sleep 3 (
) and cancel the Sleep,
Auto
"signal )
" displayed),