2N Helios IP Vario Installation Manual page 30

Door access intercom
Hide thumbs Also See for Helios IP Vario:
Table of Contents

Advertisement

®
2N
Helios IP Vario resetting procedure
®
1.
Switch 2N
Helios IP Vario off.
2.
Connect the jumper into the resetting (default setting) position (put the
display switch into the F_RES position in the display-equipped models with
535v1 and 535v2 board versions).
®
3.
Switch 2N
Helios IP Vario on and wait for the acoustic start signalling.
®
4.
Switch 2N
Helios IP Vario off.
5.
Remove the jumper from the resetting (default setting) position (put the
display switch into the NORMAL position in the display-equipped models with
535v1 and 535v2 board versions).
®
6.
Switch 2N
Helios IP Vario on.
Normal
Default
operation
settings
Table 2.5
Configuration Jumpers on Display Connector
To reset the default values of a display-equipped 2N
the display right-hand bottom corner in position F_RES. This applies to modules with
board versions 535v1 and 535v2 only. For 535v5 versions, use a jumper at connector
X19.
Mounting – Electrical Installation
Display
Display connector
connector X6
PCB version
530v2
X7
PCB version
535v1, 535v2
®
Helios IP Vario, put the switch in
2.3
Connector X13
PCB version
535v5
30