Multi-Band Transceiver System
Remote Command
Command
Valid on
Parameter
(Instruction
MBT,
Type
Code and
BDC, or
qualifier)
BUC
Retrieve
N/A
Maintenance Status
Arguments for
Command or
(Note that all arguments are ASCII numeric codes, that is,
Response to
Query
Query only.
All
MBT-4000B -
103 bytes,
Used to Query the maintenance status of the unit.
alphanumeric
Example for MBT-4000B base: <0001/RMS?{cr}
BDC –
>0001/RMS={cr}{lf}
98 bytes,
15VT1=015.1{cr}
alphanumeric
7V5T1=007.7{cr}
5VLT1=005.0{cr}
BUC –
28VT1=027.2{cr}
98 bytes,
REFVT=001.3{cr}
alphanumeric
LNA_1=000.0{cr}
LNA_2=000.0{cr}
RFSWP=B{cr}
IFSWP=N{cr}
RRFSW=B{cr}
RIFSW=B{cr}{lf}
Example for BUC: <0001A2/RMS={cr}
>0001A2/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
POUT=XXX.X{cr} (reserved for future use)
TEMP=+25.0{cr}{lf}
Example for BDC: <0001A1/RMS={cr}
>0001A1/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
LNAC=255.0{cr}
TEMP=+25.0{cr}{lf}
Note: "REFV" will show tuning voltage of reference OSC for
standalone. Otherwise REFV=xxx.x which means Not Applicable.
MN/MBT4000B.IOM
Description of arguments
ASCII codes
between 48 and 57)
A-25
Revision 0
Query
Response to
(Instruction
Command
Code and
(target to controller)
qualifier)
N/A
RMS?
Response to
query
(target to
controller)
RMS=x....x
(see description
for details of
arguments)
Need help?