Comtech EF Data MBT-4000B Installation And Operation Manual page 54

Multi-band transceiver system
Hide thumbs Also See for MBT-4000B:
Table of Contents

Advertisement

Multi-Band Transceiver System
Remote Command
Command
Valid on
Parameter
(Instruction
MBT,
Type
Code and
BDC, or
qualifier)
BUC
Retrieve next 5
N/A
All
unread Stored
Alarms
Mute State
MUT=x
BDC
BUC
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric codes, that
Response to
Query
between 48 and 57)
145 bytes
Query only
The unit returns the oldest 5 Stored Events, which have not
yet been read over the remote control. Reply format: Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body, where Sub-body=
YYYYYYYYYY ZZ hhmmss mmddyy
Where:
YYYYYYYYYY=being the fault description.
ZZ= being the alarm type.
FT = Fault
OK = Clear
IF = Information
If there are no new events, the unit will reply with LNA*
Note: See Appendix B for a description of possible
Alarm/Events that may be found in the Alarm queue.
1 byte,
Command or Query.
value of 0,1
Mute the unit, where:
0 = Disabled,
1 = Enabled
Example: MUT=1
Revision 0
MN/MBT4000B.IOM
is, ASCII codes
A-18
Query
Response to
(Instruction
Command
Code and
(target to controller)
qualifier)
N/A
LNA?
MUT= (message ok)
MUT?
MUT? (received ok, but
invalid arguments
found)
MUT* (message ok, but
not permitted in current
mode)
MUT! (command not
accepted by MBT-
4000B base unit. It
must be addressed to
BUC or BDC sub-units)
Response to
query
(target to
controller)
LNA=YY..ss
(see
description for
details of
arguments)
MUT=x
(same format
as command
arguments)