Multi-Band Transceiver System
Remote Command
Valid
Command
on
Parameter
(Instruction
MBT,
Type
Code and
BDC,
qualifier)
or
BUC
Automatic
AFR=x
All
Fault
Recovery
State
Attenuation
ATT=xx.xx
BDC
BUC
Clear All
CAA=
All
Stored
Alarms
Arguments
for
Command
(Note that all arguments are ASCII numeric codes, that is, ASCII codes
or Response
to Query
1 byte, value
Command or Query.
of 0, 1
Enable Automatic Fault Recovery on a BXC as follows:
0=Disabled
1=Enabled
Example: AFR=1
5 bytes,
Command or Query
numeric
Valid attenuation level, in dB, at 0.25dB step size as factory default.
Example: ATT=08.25
None
Command only.
Instructs the slave to clear all Stored Events.
This command takes no arguments.
9
MN/MBT4000B.IOM
Description of arguments
between 48 and 57)
Revision 0
Response to
Query
Command
(Instruction
(target to
Code and
controller)
qualifier)
AFR=(message
AFR?
ok)
AFR? (received ok,
but invalid
arguments found)
AFR*(message ok,
but not permitted in
current mode)
ATT=(message ok)
ATT? (received ok,
but invalid
arguments found)
ATT*(message ok,
but not permitted in
current mode)
ATT! (Command
not accepted by
MBT-4000B base
unit. It must be
addressed to BUC
or BDC sub-units)
CAA=(message
N/A
ok)
Response to
query
(target to
controller)
AFR=x
(same format
as command
arguments)
N/A
Need help?