D*AP LM 4
Web GUI – EVENTS – Trigger – Parameter Sources
Parameter Sources – represent the status of selected parameters from selected function blocks :
Label
Category
Subcategory
Parameter
Expression 1
Expression 2
Web GUI – EVENTS – Preset Events – System
A trigger will launch an event. The LM 4 knows four different types of events which may be set up via
page embedded tabs. Firstly we have the System tab :
Because the "SYSTEM" tab has presets only for the "Setup" sub-tab, we have just one column for
recalling systems presets if necessary.
input field for a label of a parameter trigger source
[INTERFACES / AUDIO PROCESSING]
e.g. If Category = INTERFACES, possible Subcategories are : [SDI
I/O interface 1 or AES I/O]
e.g. if Subcategory = SDI I/O Interface 1, possible parameters are:
[Status / ARIB B39 Avaialbale / ARIB B39 Block Error/ ARIB B39
Audio Mode / SDI lock]]
e.g. if Parameter = Status, possible expressions are:
[OK / Fail / Not Routed / WARNING].
The Expression allows multiple values. I.e. you may select [Fail &
Not Routed]. In that case both status expressions are marked
green and due to limited space in the pull down the word <multiple
values> will be used
This is a logical or combination. Note that you are able to logical
combine two or all of the expressions of the pulldown no matter if it
makes sense for the actual parameter source!
will be implemented soon