Web GUI – ROUTING
This tab is used to setup the routing path of the audio signal(s) through the unit.
Each functional block of the device has an input- and an output-label. The output-labels are pre-defined,
while the label of an input must be selected by the administrator in order to route the signals.
Additional blue labels give an indication of the type of signal that is expected by the respective function block
input (e.g.
1L/1R
for the DSP).
The above screen shot shows an example configuration :
DSP
AES
Delay
Interface 1
SDI I/O
the de-embedder outputs [SDI 1/2 and 3/4] are connected to the
DSP 1/2 [1/2] and 3/4 [3/4] inputs.
After processing by the DSP, these signals will leave it at the outputs
DSP 1/2 to 3/4.
the first outputs AES 1/2 is connected with DELAY 1/2 for a parallel
delay line, while AES 3/4 is not connected.
a signal pair from the AES 1/2 input will be delayed
by 150ms and is available for routing by using the label DELAY 1/2.
DSP 1/2 and DSP 3/4 are both connected with the embedder input
EMB 1/2 and EMB 3/4.
Where these signals will be embedded must be defined on the
respective setup pane :
INTERFACES > SDI I/O Interface > Embedder.