7.2.3 Connecting the Communication Wiring

Multiple inverters could be monitored via RS-485 connection (Figure 5-6), but
each inverter's ID must be set.
NOTE:
Make sure the inverter ID is different from each other in the same train.
Single inverter could be monitored RS-485 connection.

7.2.4 Inverter ID Setting

1.
Turn on DC power and wait for the LCD display to be ok, then press
"Select" button until "Inverter ID: XX" is shown in the LCD.
2.
Press and hold both buttons ("Enter" first then "Select") until entering
setting ID screen, then you could release the both buttons and set ID by
pressing "Select" button, press "Enter" button if the ID is correct (ID = 1 ~ 254).
3.
Inverter ID is changed and saved.

7.3 LCD flowchart

Press any button will enter menu page (Figure 7-5), Today Output Energy is
home page, and several item is described in section 7.3.1 ~ 7.3.6.
Figure 7-4 Inverter ID Setting