Gas Conversion And Specifications; Conversion Procedure - Waldorf RN8510GE Installation And Operation Manual

800 series gas ranges electric static/convection oven
Hide thumbs Also See for RN8510GE:
Table of Contents

Advertisement

Conversion Procedure

Ensure that the Appliance is isolated from the gas supply before commencing
servicing.
NOTE:

These conversions should only be carried out by qualified persons.
checked for leaks before re-commissioning the appliance.

Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) can only be
adjusted in accordance with the following instructions and shall be re-sealed before
re-commissioning this appliance.

For relevant gas specifications refer to
Open Burners.
1.
Remove the pot stands, burner caps and burner bodies and the pot stand supports.
2.
Remove injectors and replace with correct size injectors as shown in 'Gas Specifications Tables' at
end of this section.
For F Options Only,
Unscrew and remove Main Injectors.
For PF Options Only,
Unscrew and remove Main and
Pilot Injectors.
3.
Refit the pot stand supports, pot stands, burner caps and burner bodies.
4.
Re-light main burners and check flame size on simmer (LOW) position.

Adjust low fire adjustment screw on open burner gas control valves to
obtain desired flame size.
NOTE: The 'Low Fire Screw' should be sealed with coloured paint on completion of low fire
adjustment.

Gas Conversion and Specifications

Caution
'Gas Specifications Tables'
27
All connections must be
at end of this section.
Low Fire Screw