Gas Regulator

- NAT Gas / LPG / Butane Only.
NOTE: The gas regulator supplied is
convertible
between
Gas and LP Gas, but it's outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn 'On' gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure operating pressure at manifold test point
with two burners operating at 'High Flame' setting.
4.
Verify operating pressure remains correct (Re-adjust regulator
if required).
5.
Screw cap nut back onto regulator.
Gas Type Identification Label
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a 'Commissioning' check of appliance as shown in Installation Section of this manual.
3.
Ensure any paint sealed components are re-sealed on completion of adjustments.
Gas Conversion and Specifications
Natural
Warning
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
29