7-2. Operation Data

<Cooling> RAS-M14GAV-E, RAS-M14GACV-E
Temperature
No.of
condition (°C)
operating
units
Indoor
Outdoor
1 unit
27 / 19
35 / –
2 units
<Heating> RAS-M14GAV-E
Temperature
No.of
condition (°C)
operating
units
Indoor
Outdoor
1 unit
20 / –
7 / 6
2 units
<Cooling> RAS-M18GAV-E, RAS-M18GACV-E
Temperature
No.of
condition (°C)
operating
units
Indoor
Outdoor
1 unit
27 / 19
35 / –
2 units
<Heating> RAS-M18GAV-E
Temperature
No.of
condition (°C)
operating
units
Indoor
Outdoor
1 unit
20 / –
7 / 6
2 units
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 7.5 m × 2 units
Operating combination
Standard
(Unit)
pressure
A
B
P (MPa)
10
0.7 to 0.9
13
0.9 to 1.1
10
10
0.9 to 1.1
13
10
0.9 to 1.1
Operating combination
Standard
(Unit)
pressure
A
B
P (MPa)
10
2.2 to 2.4
13
2.5 to 2.7
10
10
1.9 to 2.1
13
10
1.9 to 2.1
Operating combination
Standard
(Unit)
pressure
A
B
P (MPa)
10
0.9 to 1.1
13
0.8 to 1.0
16
0.8 to 1.0
10
10
0.9 to 1.1
13
10
0.9 to 1.1
13
13
0.9 to 1.1
16
10
0.9 to 1.1
Operating combination
Standard
(Unit)
pressure
A
B
P (MPa)
10
3.2 to 3.4
13
3.4 to 3.6
16
3.4 to 3.6
10
10
2.6 to 2.8
13
10
2.6 to 2.8
13
13
2.6 to 2.8
16
10
2.6 to 2.8
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
11 to 13
43 to 45
8 to 11
47 to 49
14 to 16
47 to 49
14 to 16
47 to 49
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
36 to 38
0 to 2
41 to 43
–1 to 1
30 to 32
–1 to 1
30 to 32
–1 to 1
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
11 to 13
41 to 43
8 to 10
45 to 47
7 to 09
47 to 49
11 to 13
48 to 50
11 to 13
48 to 50
11 to 13
48 to 50
11 to 13
48 to 50
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
44 to 46
0 to 2
50 to 53
0 to 2
51 to 53
0 to 2
37 to 39
–1 to 1
38 to 40
–1 to 1
38 to 40
–1 to 1
38 to 40
–1 to 1
– 30 –
Compressor
Indoor
Outdoor
revolution
fan
fan
(rps)
High
700rpm
39
High
750rpm
66
High
750rpm
64
High
750rpm
65
Compressor
Indoor
Outdoor
revolution
fan
fan
(rps)
High
750rpm
60
High
750rpm
76
High
750rpm
78
High
750rpm
80
Compressor
Indoor
Outdoor
revolution
fan
fan
(rps)
High
700rpm
35
High
750rpm
58
High
750rpm
75
High
750rpm
71
High
750rpm
71
High
750rpm
71
High
750rpm
71
Compressor
Indoor
Outdoor
revolution
fan
fan
(rps)
High
750rpm
62
High
750rpm
81
High
750rpm
85
High
750rpm
93
High
750rpm
101
High
750rpm
101
High
750rpm
101