7-2. Operation Data

<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
AMP Air Conditioning
Model name
Standard
RAS-
pressure
P (MPa)
05BKVG-E
1.2 to 1.3
07BKVG-E
1.1 to 1.3
1.1 to 1.3
10BKVG-E
13BKVG-E
1.0 to 1.1
1.0 to 1.1
16BKVG-E
Model name
Standard
RAS-
pressure
P (MPa)
05BKVG-E
2.1 to 2.2
07BKVG-E
2.1 to 2.4
2.4 to 2.6
10BKVG-E
13BKVG-E
2.6 to 2.7
2.8 to 2.9
16BKVG-E
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
43 to 45
13 to 15
11 to 13
47 to 49
11 to 13
59 to 51
9 to 10
51 to 52
9 to 10
47 to 58
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
34 to 36
1 to 2
0 to 1
35 to 40
40 to 42
0 to 1
43 to 44
0 to 1
45 to 47
1 to 2
- 27 -
www.ampair.co.uk | sales@ampair.co.uk
FILE NO. SVM-16030-2
Indoor
Outdoor
fan mode
fan mode
High
High
High
High
High
High
High
High
High
High
Indoor
Outdoor
fan mode
fan mode
High
High
High
High
High
High
High
High
High
High
Compressor
revolution
(rps)
36
52
52
78
86
Compressor
revolution
(rps)
51
65
68
73
84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents