No.
Part name
Front panel
4) Press "
1
(Continued)
5) Remove the front panel fixing screws.
6) Press the electric parts box with the right
<How to assemble the front panel>
1) Press three center positions and two lower center positions of the air outlet, and
2) Insert the electric dust collector and left and right air filters.
3) Tighten two screws.
Procedures
" part under the front panel
and remove hooks of the front panel from
the installation plate.
Installation plate
Front panel
Press
(2 pcs.)
thumb while pulling the both sides of the
front panel toward you.
Holder
Holder
Holder
then hang the hanging hooks (4 pcs.) at the top side of the front panel to the rear
plate.
Press in the electric dust collector until the protrusions on both sides are completely
inserted into the holders.
If installation is incomplete, the FILTER indicator (orange) may light.
• Incomplete hanging or incomplete pressing may cause a dewdrops or generation
of a fluttering sound.
Electric dust
Electric dust
Electric dust
Electric dust
Electric dust
Electric dust
collector
collector
collector
Protrusion
Protrusion
Protrusion
– 100 –
Remarks
Pull here
Press here
collector
collector
collector
Holder
Holder
Holder
Protrusion
Protrusion
Protrusion
Press here