Toshiba RAS-B10GKVP-E Service Manual page 96

Split type heat pump type/cooling onlytype
Hide thumbs Also See for RAS-B10GKVP-E:
Table of Contents

Advertisement

11-10-3. Indoor Unit (Other Parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC) sensor
2
Remote controller
3
Louver motor
MP24Z
4
Indoor fan motor
11-10-4. Outdoor Unit
No.
Part name
1
Compressor
(Model : DA111A1F-20F)
2
Compressor
(Model : DA130A1F-25F)
3
Outdoor fan motor
(Model : ICF-140-43-4R)
4
Compressor thermo. bimetal type
(Model : US-622KXTMQO-SS)
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC (kΩ)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
White
1
1
Yellow
2
2
Yellow
3
3
Yellow
4
4
Yellow
5
5
Refer to 11-5-1. (3) and (4).
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
White
Black
Check conduction by using the tester.
– 96 –
Checking procedure
10°C
20°C
25°C
20.7
12.6
10.0
Position
1 to 2
1 to 3
1 to 4
1 to 5
Checking procedure
Position
Red - White
White - Black
Black - Red
Position
Red - White
White - Black
Black- Red
Position
Red - White
White - Black
Black- Red
30°C
40°C
7.9
4.5
Resistance value
380 ± 40 Ω
Resistance value
0.88 to 0.98 Ω
Under 20°C
Resistance value
0.69 to 77 Ω
Under 20°C
Resistance value
17 to 25 kΩ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents