9-3-2. How to Cancel the Auto Restart Function

To cancel auto restart function, proceed as follows :
Repeat the setting procedure : the unit receives the signal and beeps three times.
The unit will be required to be turned on with the remote controller after the main power supply is turned off.
• When the system is on stand-by (not operating)
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
• When the system is operating
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)

9-3-3. Power Failure During Timer Operation

When the unit is turned off because of power failure
during timer operation, the timer operation is
cancelled.
In that case, set the timer operation again.
NOTE :
The Everyday Timer is reset while a command
signal can be received from the remote controller
even if it stopped due to a power failure.
The unit is on standby.
The unit starts to operate.
After approx. three seconds,
The unit beeps three times and continues to operate.
If the unit is not required to operate at this time, press [RESET] button
once more or use the remote controller to turn it off.
The unit is in operation.
The unit stops operating.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.

9-4. FILTER Indicator

When the elapsed time reaches 1000 hours after air
purifier operation, the FILTER indicator lights.
After cleaning the filters, turn off the FILTER indicator.

9-4-1. How to Turn Off FILTER Indicator

Press [RESET] button on the indoor unit.
NOTE :
If [RESET] button is pushed while the FILTER indica-
tor is not lit, the indoor unit will start the automatic
operation.
When you want a temporary operation while the
FILTER lamp lights, press [RESET] button to turn off
the FILTER lamp. (See page 48)