6-2. Operation Data
<Cooling>
Temperature
Model
condition (°C)
name
RAS-
Indoor
Outdoor
10JKVP-E
27/19
35/–
13JKVP-E
<Heating>
Temperature
Model
condition (°C)
name
RAS-
Indoor
Outdoor
10JKVP-E
20/–
7/6
13JKVP-E
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.9 to 1.1
12 to 14
0.8 to 1.0
10 to 12
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
2.2 to 2.4
37 to 38
2.5 to 2.7
42 to 44
– 19 –
Indoor fan
Outdoor fan
mode
T2 (°C)
41 to 43
High
43 to 45
High
Indoor fan
Outdoor fan
mode
T2 (°C)
2 to 4
High
0 to 3
High
Compressor
revolution
mode
(rps)
High
47
High
72
Compressor
revolution
mode
(rps)
High
61
High
79