No.
Part name
Electric parts
1) Follow the procedure up to 4) in
3
box assembly
2) Remove screw of earth lead attached to the
3) Remove the lead wire cover, and remove
4) Pull out TC sensor from sensor holder of the
5) Disengage the two claws at the top of the
6) Remove the fixing screw that secures the
<How to assemble the electric parts box>
1) Hook the top part of the electric parts box
2) Secure the grounding wire using the fixing
Procedures
end plate of the evaporator.
connector (5P) for the fan motor and
connector (5P) for the louver motor from the
electric parts box assembly.
evaporator.
display unit.
(They can be easily disengaged by pressing
the drain pan above the claws and at the same
time pulling the display unit toward you.)
electric parts box assembly, and remove the
assembly.
assembly onto the claws on the back body,
and secure it using the fixing screw.
Now attach the display unit.
Connect the connectors for the fan motor
and louver motor.
screw.
Insert the TC sensor into the sensor holder.
∗ Be absolutely sure to loop the grounding
wire and TC sensor leads once at the
bottom.
above.
2
– 102 –
Remarks
Lead wire
cover
TC sensor
TC sensor
Fan motor
Fan motor
connector
connector
Louver motor
Louver motor
connector
connector
Screw
Fixing screw
Make absolutely sure that
the leads form a loop
Press the
Press the
drain pan
drain pan
Pull the display
unit toward you