No.
Part name
Bearing
1) Follow to the procedure in the items
6
2) Remove the two fixing screws used to secure
the left edge panel of the heat exchanger, and
remove the two screws used to secure the
bearing base.
3) Raise the left side of the heat exchanger
slightly, and remove the bearing base.
<Caution at assembling>
• If the bearing is out from the housing, push it
into the specified position and then incorporate it
in the main body.
• After assembling the bearing base, check that it
is fitted into the stepped part of the drain pipe.
Procedures
Drain pipe
Bearing base