Viessmann Vitodens 200-W Installation Instructions Manual page 59

45 and 60 kw wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Further details regarding the individual steps
D Heating circuit pump "OFF"
E Heating circuit pump "ON"
Changing the standard set room temper-
ature
Operating instructions
Reduced set room temperature
90
A
C
D
Example 2: Adjustment of the reduced
set room temperature from 5 °C to
14 °C
A Boiler water temperature or flow
temperature in °C
B Outside temperature in °C
C Set room temperature in °C
D Heating circuit pump "OFF"
E Heating circuit pump "ON"
Changing the reduced set room temper-
ature
Operating instructions
-20
B
E
Commissioning, inspection, maintenance
(cont.)
Changing the slope and level
Individually adjustable for each heating
circuit.
90
+20
Outside temperature in °C
A Changing the slope
B Changing the level (vertical parallel
offset of the heating curve)
Extended menu:
1. å
2. "Heating"
3. Select heating circuit.
4. "Heating curve"
5. "Slope" or "Level"
6. Select heating curve according to the
system requirements.
3.5
1.4
A
B
0.2
-20
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 200-w b2ha-45Vitodens 200-w b2ha-60

Table of Contents