Troubleshooting
Fault codes
(cont.)
Dis-
Const.
played
fault
code
bb
bC
122
Weath.-
System char-
comp.
acteristics
X
Mixer regulates
to 20 °C flow
temperature.
X
Control mode
without remote
control
Cause
Measures
Communica-
Check extension
tion error, ex-
kit connections and
tension kit for
code.
heating circuit
3 (with mixer)
Communica-
Check connec-
tion error,
tions, cable, coding
Vitotrol re-
address "A0" in
mote control,
"Heating circuit"
heating circuit
group and remote
1 (without
control settings
mixer)
(see page 160).
For wireless re-
mote controls:
Check radio path
connections, place
wireless remote
control and wire-
less repeater close
to the boiler. Check
KM BUS connec-
tion to wireless
base station. Re-
place the wireless
components.