Specifications; Testing The Tranz 460/Tranzport 232 Connection - VeriFone TRANZ 460 Reference Manual

Fdc retail/debit purchasing card
Hide thumbs Also See for TRANZ 460:
Table of Contents

Advertisement

Testing the TRANZ
460/TRANZport 232
Connection

Specifications

Physical
Environmental
Power
Port Configurations
F - 4
FDC Retail/Debit Purchasing Card Reference Manual
After connecting the TRANZport as previously outlined, the following TCL
code can be used to test the system.
Using the standard recall and edit capabilities of the TRANZ 460, load
memory locations 31 and 32 with the following TCL command strings:
031=B1.1GR'B PORT TEST'R13R10*R5+R1*I
032=B1.1GR'A PORT TEST'R13R10*R5+R0*I
To test the TRANZport 232 B port, press the [FUNC/ENTER] key then the
[1] key on the TRANZ 460 terminal. This sends 'B PORT TEST' to the
device connected to the B port at 9600 baud.
To test the A port, press the [FUNC/ENTER] key and then the [2] key on the
TRANZ 460. This sends 'A PORT TEST' to the device connected to the A
port at 9600 baud.
When the TRANZ 460 is in the Idle Mode, the TRANZport 232 is connected
to the B port.
Height: 1.5 in. (38.1 mm)
Width: 3.5 in .(88.9 mm)
Depth: 4.0 in. (101.6 mm)
Shipping Weight: 1.75 lb (0.8 kg), including cables and power supply
Operating Temperature: 0
Operating Humidity: 20% to 90%, no condensation
Voltage: 120 VAC, 60 Hz
240 VAC, 50 Hz; 220 VAC, 50 Hz
200 VAC, 50 Hz
Terminal Input Port (9-pin D-sub male connector)
pin 1
RTS
pin 2
TxD (from terminal)
pin 3
RxD (to terminal)
pin 4
CTS
pin 5
Signal Gnd
pin 6
RTS (duplicate)
pin 7
DCD
pin 8
RTS (duplicate)
pin 9
DTR
TRANZ 460 Terminal
o
o
o
o
to 40
C (32
to 104
F)