Multi protective function

1.1 Anti-freezing protecting control:
When the ambient temperature is low while in Air Conditioner or Dehumidifier mode, the
compressor and water pump will stop working if the copper coil temperature is too low. When
the copper coil temperature increases, the operation will resume.
1.2、Water-full protection:
When the water level in the internal / or external water tank is surpassing the maximum
level, the unit will alert automatically and E4 will be displayed on the LED screen. Please
discharge water in the machine according to "Water Drainage" section.
1.3 Compressor protection
Compressor has an overheating protection function and may stop to prevent compressor
damage. Also the compressor runs under a 3 minute delay protection function.
Your AirCube an advanced self-evaporative air conditioner, which reduces the need to empty the
water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the
condenser coils and any excess is evaporated.
Manual drainage:
1.1 When either the internal or the external water tank is full the unit will stop working.
1.2 Shut off the unit and unplug. Remove the rubber water stopper and leave the internal
tank to drain in the external tank for at least 30 minute. Try not to move the
model abruptly as this may cause water to spill out from internal water tank.
1.3 Empty the external tank
1.4 Put the rubber water stopper back (or not if using next in dehumidifier mode).

WATER-DRAINAGE

Ensure the rubber water stopper is in place and
do not use continuous drainage if you intend to
use the self-evaporating facility for improved
cooling effect.