Removing 2.5-Inch Hdd / Ssd Modules; Preliminary Steps - Fujitsu Primergy RX4770 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for Primergy RX4770 M1:
Table of Contents

Advertisement

Hard disk drives / solid state drives
7.3

Removing 2.5-inch HDD / SSD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.3.1

Preliminary steps

Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS utility.
V
CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
112
Procedure
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a RAID array
81.
RX4770 M1

Advertisement

Table of Contents
loading

Table of Contents