Operating Instructions
Delay Start Operation
To program
delay start:
1.
Turn unitoff(pressOFFpad).
2.
Press DELAY START pad. Display flashes currently
programmed temperature setting.
3.
Program new temperature setting (if desired) using
Vl Apad.
NOTE: Current temperature setting is used if not
changed within 5 seconds.
4.
Select desired operating mode and fan speed.
5.
Press DELAY START pad. Display flashes currently
programmed delay time_l
through 24 (hours).
6.
Program new delay time (if desired) using V
I/_
pad.
NOTE: Current delay time is used if not changed within
5 seconds.
7.
Press DELAY START pad to start timer. Display
shows time remaining until unit automatically starts.
At programmed time, unit automatically starts in
programmed operating mode.
NOTE: Timer automatically starts after 5 seconds if
DELAY START pad is not pressed.
To program automatic stop:
1.
Start air conditioner in desired operating mode. If
unit is already in desired mode, go to step 2.
2.
Press DELAY START pad. Display flashes currently
programmed time_l
through 24 (hours).
3.
Program new time (it desired) using V
I A pad.
NOTE: Current time is used if not changed within 5
seconds.
4.
Press DELAY START pad to start timer. Display
shows time remaining until unit stops. When
programmed time elapses, unit automatically stops.
NOTE: Timer automatically starts after 5 seconds if
DELAY START pad is not pressed.
To cancel delay stop program, press DELAY START pad
after timer starts counting down, or turn unit off (press
OFF pad).
Adjusting
Airflow
Direction
See Figure 38. Position of air discharge vent louvers
determines direction of airflow from vent. Direction can
be adjusted upward, downward, left, and right.
Figure 38. Airflowfrom Air Discharge Vent
1. Airflow directioncontrol lever
2. Air discharge vent hodzontal louvers
2
To adjust airflow upward or downward, move horizontal
louvers on outside of air discharge vent up or down.
To adjust airflow left or right, move airflow direction control
lever left or right.
Energy
Saving
Tips
In addition to operating air conditioner in energy-saving
mode, savings of energy and money can be realized by:
• Increasing insulation in walls and ceilings.
• Closing all heating and ventilation diffusers or vents
(including furnace cold air retum vent) in area being
cooled.
• Closing drapes or blinds on windows that receive
direct sunlight. Install window coverings or awnings
on windows not currently covered.
• Adequately ventilating attic. Heat build-up in attic adds
to air conditioner cooling load.
• Avoiding use of heat-producing appliances during
hottest parts of day.
• Turning off lightsand appliances when not needed.
• For maximum efficiency and cooling, vent door should
be closed whenever air conditioner is cooling.

Hide quick links: