Installation
Figure 34. Secudng Outer Case in Wall Opening
1. Lintel and flashing (if required)
2. Provide %" slope to outside for condensate drainage
3. Attach outer case to framing in two places on each
side of case
4. Completely caulk or seal all four sides of outer case
5. Outer case extends into room _"
5
i
%
%
Masonry
Construction
See Figure 32 for dimensions of finished opening to cut
out or build into masonry wall. Seal outer case in place
with mortar or secure to wall with concrete nails driven
through sides of case.
NOTE:
Ifsecudng case with concrete nails, pre-drill
holes in case before driving nails into wall.
Installation
in Walls Exceeding
Outer Case Dimensions
Air conditioner must be installed so air flows freely
through side louvers to prevent overheating of
compressor and fan motor. If dimensions of wall restrict
airflow to louvers, wall opening must be modified by
chamfering vertical portions of outside opening, as
shown in Figures 35 and 36.
Figure 35. Chamfering Walls That Exceed Outer Case
Dimensions (Top View)
1. Outer case extends into room sA"
2. Distance from front of outer case to side louvers
f2000 Btu
18000 Btu
I
I
9 inches
14Y2inches
3. Caulk around outer case to seal in place
4. Mortar
5. 4" clearance required for unrestricted air flow
6. Side louvers
Figure 36. Chamfering Walls That Exceed Outer Case
Dimensions (Side View)
1. Outer case extends into room _"
2. Distance froom front of outer case to side louvers
12000 Btu
I
18000Btu
1
9 inches
14V2 inches
3. Caulk around outer case to seal in place
4. Install outer case with %" slope to outdoor side
5. install lintel and/or flashing, if necessary
4
5
_<----
2
!