MLP 101 AAP, cont'd
4.
Repeat steps 1 through 3 to mount any other AAPs. Cover
any openings in the faceplate with blank plates (provided).
5.
If it was not done previously, adjust the MLP 101 AAP
from its rear panel. See the previous section,
"Adjusting the MLP 101 AAP" for detailed instructions.
6.
Pretest the MLP 101 AAP before final mounting of the
faceplate.
7.
Perform the final mount by attaching the cabled device
faceplate or AAP wall plate into a wall or piece of
furniture. For detailed installation information, refer to the
installation guide shipped with the faceplate.

Remote Control

The wiring and control options described below pertain to all
models in the MLP 101 series.

Remote connector wiring

Pin 1 is 10 VDC reference voltage. Pin 2 is volume control DC
voltage; range is 0 to 10 V, where 0 V is mute and 10 V provides
maximum volume. Pin 3 is ground.
N
All nominal levels are at ±10%.
REMOTE
1
2
3
10V
VOL/MUTE
MAX
2K
10K
MUTE
MIN
MLP 101 Series • MLP 101 AAP
3-6
1
2
3
GND

Remote control options

The MLP 101 AAP has three remote control options:
1.
The Extron VCM 100 volume/mute controller and
VC 50 volume controller use a 10k ohm potentiometer as
the main method for controlling volume levels.
The VCM 100 includes an illuminated Mute button and
operates in sync with the MLP 101 AAP.
2.
The Extron MLA-VC10 converts RS-232 serial command
to 0~10 volt variable DC for volume control.
3.
Generic volume/mute controllers are standard 10k ohm
potentiometers.
MLP 101 Series • MLP 101 AAP