  • Page 1 User Guide Distribution Amplifiers MTP DA4 and MTP DA8 Twisted Pair Distribution Amplifiers 68-975-01 Rev. E 06 12...
  • Page 2 Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source indicated on the product. This This symbol is intended to alert the user of important operating and mainte- equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third nance (servicing) instructions in the literature provided with the equipment.
  • Page 3: Conventions Used In This Guide

    ATTENTION: Attention indicates a situation that may damage or destroy the product or associated equipment. NOTE: A note draws attention to important information. Copyright © 2012 Extron Electronics. All rights reserved. Trademarks All trademarks mentioned in this guide are the properties of their respective owners.
  • Page 5: Table Of Contents

    Contents Introduction ............1 About the MTP DA4 and MTP DA8 ..... 1 TP Cable Advantages .......... 2 Transmission Distance ........2 Termination and Mute Jumpering — MTP 15HD Systems Only ........4 Installation and Operation ........6 Connections ............6 Power Supply Wiring ........
  • Page 6 MTP DA4 and MTP DA8 • Contents...
  • Page 7: Introduction

    About the MTP DA4 and MTP DA8 The Extron MTP DA4 and MTP DA8 twisted pair (TP) distribution amplifiers (DAs) distribute a single TP input signal to four or eight MTP receivers. The TP input can be from any of the following MTP transmitter and switcher families: MTP T SV —...
  • Page 8: Tp Cable Advantages

    500 feet 600 feet 1024 x 768* (90 m) (105 m) (150 m) (185 m) <300 feet >350 feet 400 feet 500 feet 1280 x 960* (90 m) (105 m) (120 m) (150 m) MTP DA4 and MTP DA8 • Introduction...
  • Page 9 1600 x 1200* 150 feet 1360 x 765 200 feet 1920 x 1080 150 feet NOTE: Resolutions marked with an asterisk (*) in the above table have the same range specification at 75 Hz. MTP DA4 and MTP DA8 • Introduction...
  • Page 10: Termination And Mute Jumpering - Mtp 15Hd Systems Only

    Audio Jumper Block J9 (Default) Inside Box Jumper Block J3 Inside Box A /V A /V 0 .9 Remove 6 screws, lift top straight up. Figure 2. Opening the DA and Termination Jumpering MTP DA4 and MTP DA8 • Introduction...
  • Page 11 2. If any mounting brackets were removed in Reinstall the six screws removed in step 1, put them back into position as you reinstall the screws. If applicable, reinstall the DA and reconnect all cables. MTP DA4 and MTP DA8 • Introduction...
  • Page 12: Installation And Operation

    Connect the free ends of the same cables carrying the distributed video or audio/serial TP link to the RJ-45 connectors on the receivers (see TP Cable Termination on page 8 to wire the RJ-45 connectors). MTP DA4 and MTP DA8 • Installation and Operation...
  • Page 13: Power Supply Wiring

    2-Pole Captive Screw Connector Tie Wrap SECTION A–A 3/16” (5 mm) Max. Smooth Ridges Power Supply Output Cord Figure 5. Power Connector Wiring MTP DA4 and MTP DA8 • Installation and Operation...
  • Page 14: Tp Cable Termination

    DA routes the serial link one way only, from the transmitter to the receivers. Also, the transmitter and receiver must be jumper configured to pass the serial link one way only (see the MTP 15HD RS Series User Guide). MTP DA4 and MTP DA8 • Installation and Operation...
  • Page 15 Brown Brown Audio right – Audio right – NOTE: If you are using Enhanced Skew-Free™ AV cable, use the TIA/EIA T 568A standard only. Figure 6. TP Cable Termination MTP DA4 and MTP DA8 • Installation and Operation...
  • Page 16: Front Panel Power Indicator

    Adding a skew compensation cable equal to the length of pair skew to the video output of the receiver • Installing an SEQ 100 15HD Skew Equalizer on the video output of the receiver and adjusting the skew for the leading video image MTP DA4 and MTP DA8 • Installation and Operation...
  • Page 17: Reference Information

    Number/signal type ......1 set of proprietary analog signals Connectors ........1 female RJ-45 Video output — see receivers specifications Number/signal type MTP DA4 ......... 4 sets of proprietary analog signals MTP DA8 ......... 8 sets of proprietary analog signals Connectors MTP DA4 ......... 4 female RJ-45 MTP DA8 .........
  • Page 18 Contact closure pin configurations MTP DA4 ......... 1 = mute output 1, 2 = mute output 2, 3 = mute output 3, 4 = mute output 4, 5 = mute all outputs, 6 = GND MTP DA8 ......... 1 = mute output 1, 2 = mute output 2, 3 = mute output 3, 4 = mute output 4,...
  • Page 19: Part Numbers

    MTP DA Distribution Amplifier Part Number MTP DA4 60-685-01 MTP DA8 60-686-01 Included Parts These items are included in each order for MTP DA4 and MTP DA8: Included Parts Part Number 12 VDC power supply MTP DA4 28-071-57LF MTP DA8...
  • Page 20: Connectors

    Four self-adhesive rubber feet are included with the DA. For tabletop use, attach one foot to each corner of the bottom side of the unit and place the unit in the desired location. MTP DA4 and MTP DA8 • Reference Information...
  • Page 21: Extron Warranty

    Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.