9. Add processed barcode string from above to output buffer.
10. Add suffix string to output buffer.
11. Add a terminating NUL to the output buffer, in case the data is processed as a string.
12. If key output is enabled, start the process to output keys. If control characters are encountered:
If Translate All is set, key is translated to CTRL + char, and output.
l
If Translate All is not set, and key has a valid VK code, key is output.
l
Otherwise, key is ignored (not output).
l
The barcode data is ready to be read by applications.

Factory Default Settings

Main Tab
Port 1
Port 2
Send Key Message (WEDGE)
Single Scan
On Delay MS
COM Ports (COM1,COM3)
Baud Rate
Stop Bits
Parity
Data Bits
Power on Pin 9
Enable handshaking
Barcode Tab
Enable Code ID
Disabled
COM1
Enabled
Off
3000
9600
1
None
8
COM1: On
COM3: Off
Disabled
None
3-123