lP GAS SYSTEM
The detector is powered by the motor home an4 chassis 12-volt DC battery
systems. A power switchjs located Qn the panel. A green light on the detector
front panel indicates that the detector has power. If the power switch is OFF,
gas flow from the tank is tut offby a special solenoid valve located at the tank.
Test the leak detector each ti l1l e you relocate and use the motor home .
. Testing Proceduie:
Hold a butane-fueled pocket lighter near the sensor.
Open the lighter valve without striking the flame. The leak
detector should respond within a few secon4s.
To reset the alarm, turn the detector OFF and back ON
again.
Lightly fan the area around the detector to insure complete
. dispersion of the gas from the lighter, and to prevent
another sounding of the alarm.
A silence button allows you to temporarily quiet the alarm for 60 seconds
after it has been set off or after testing.
If the alarm does not sound duting
.<\
test or if the green indicator light is not
visible, see your dealer or an authorized Fleetwood Service Center. There
an~
no batteries or user serviceable parts inside the unit.
NOTE: Remember to turn off the detector if you are not using
ypur motor home. The detector draws enough current to_
discharge your battery.
=============