Lexmark X746de Service Manual page 90

Hide thumbs Also See for X746de:
Table of Contents

Advertisement

7526
Step
Questions / actions
Check for the following continuity between the
7
DC autoconnect and JFUSER1 on the system
board.
Is continuity present?
Check for continuity between the following
8
pins of the AC autoconnect and the pins of
the connector that connects to the LVPS.
Is continuity present?
Service Manual
2-50
DC auto-
JFUSER1
connect
Pin 9
Pin 9
Pin 10
Pin 10
LVPS
AC Auto-
connect
connect
Pin 1
Pin 5
Pin 3
Pin 1
Yes
Go to step 8.
Replace the system board.
See
"System board
removal" on page
4-165.
No
Replace the fuser DC
cable. See
"Fuser DC
cable removal" on
page
4-115.
Replace the fuser AC
cable. See
"Fuser AC
cable removal" on
page
4-113.
Previous
Next
Go Back

Advertisement

Table of Contents
loading

This manual is also suitable for:

X748dteX748de

Table of Contents