7526
Installation notes:
•
When installing the new LVPS, make sure the voltage switch (A) is set for the proper value (115 V or
230 V), depending on the country.
Install the LVPS, and make sure the fuser AC cable is in the cable guides, and not behind the LVPS.
•
Reconnect the fuser AC cable to the LVPS.
•
Replace the five LVPS mounting screws.
•
Reconnect the cable in connector JLVPS1 on the system board.
•