Gree GC201306 -1 Service Manual page 168

Super free match series, t1/r410a/50hz
Table of Contents

Advertisement

Super Free Match
Service Manual
6. Unscrew the
fixed screws of
drainage pump
7. Remove drainage
pump and replace it
8.Connect the water
pipe to the drainage
pump
9. Install the drain
pan and the bracket of
the filtering screen.
10. Install the front
panel assembly.
11. Install the front
panel
MAINTENANCE
164
 
Unscrew the fixed screws of
drainage pump
Remove drainage pump and
replace it
Connect the water pipe to the
water pump and then screw
the screws around it.
Place the drain pan and the
bracket of the filtering screen
at the original position, and
then screw the screws around
them with a screwdriver.
Place the front panel assembly
at the original place and screw
the screws around it
Put the front panel at the
original place, and press the
locks at both ends to secure it.