Optional Operation - Gree GC201306 -1 Service Manual

Super free match series, t1/r410a/50hz
Table of Contents

Advertisement

Super Free Match
Service Manual
 
5) Press
3.2.3 Guide for Optional Operation
1)
About X-FAN
This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit is stopped
to avoid mould.
◆ X-FAN ON: When press the ON/OFF button to turn off the unit, the indoor fan will continue running
for about another 10 minutes at the low speed. In this case, the indoor fan can be stopped directly by
pressing the button X-FAN.
◆ X-FAN OFF: When press the ON/OFF button to turn off the unit, the whole unit will be stopped
completely.
2)
About AFTERHEAT X-FAN
Under the Heat mode or Auto Heat mode, if the unit is turned off, the compressor and outdoor fan will stop
running immediately and the upper and lower guide board will rotate to the horizontal position, while the indoor
fan will still run at the low fan speed. Then, 10 seconds later, the unit will stop completely.
3)
About AUTO RUN
When AUTO RUN is selected, the setting temperature will not be displayed on the LCD and the unit will
choose the suitable running mode automatically in accordance with the room temperature.
◆ About TURBO
If this function is activated, the unit will run at super-high fan speed to cool or heat quickly so that the
ambient temperature will approaches the preset temperature as soon as possible.
CONTROL
42
to select the swing angle.