Gree GC201306 -1 Service Manual page 167

Super free match series, t1/r410a/50hz
Table of Contents

Advertisement

6.2.3 One-way cassette type
◆ Assembly and Disassembly of the Water Pump
Remark:
Prior to the assembly of the
Steps
1.
Remove the front
panel.
2. Unscrew the fixed
screws
 
3. Remove the front
panel assembly.
4. Unscrew the fixed
screws
 
5. Remove the drain
pan and the bracket
of the filtering
screen.
drainage
pump, make sure the power supply is cut off.
Illustrations
Super Free Match
Service Manual
Operation Instructions
Slight press the locks at both
ends of the front panel to open
one side of it, and then undo
three clasps to open the other
side of the panel, after that,
remove the panel upward
away from the unit.
Unscrew the fixed screws of
the front panel and main body
of the unit
Remove the front panel
assembly upward away from
the unit.
Unscrew the screws around
the drain pan
Remove the drain pan and the
bracket of the filtering screen
upward away from the unit.
163