Gree GC201306 -1 Service Manual page 160

Super free match series, t1/r410a/50hz
Table of Contents

Advertisement

Super Free Match
Service Manual
4.Disconnect the left
side plate and rear side
plate
6.1.2 Assembly and Disassembly of the Compressor
Remarks: Prior to the assembly of the compressor, make sure there is no refrigerant in the pipeline and the power
supply is cut off.
Steps
1.Remove the
power code of the
compressor
2.Remove the
connecting pipe
of the compressor
MAINTENANCE
156
Illustrations
a)
Unscrew the fixed screws of
left side plate and rear side
plate;
b)
Remove left side plate and rear
side plate.
Operation Instructions
a)
Unscrew the fixed
screws of
power
code;
b)
Remove the power
code.
Note: when removing the
power cord, please label
the power cord and the
terminals to avoid
misconnecting next time.
a)
Solder the joint of
connecting pipe of
the compressor.
b)
Pull out the
connecting pipe
Note: never let the flame
contact any other
component.