Single Ups Unit System Oneline Configurations - Eaton 9395 UPS Installation And Operation Manual

450–825 kva powerware series
Hide thumbs Also See for 9395 UPS:
Table of Contents

Advertisement

UNDERSTANDING UPS OPERATION
6.3

Single UPS Unit System Oneline Configurations

Oneline Drawing
Figure 6‐5 on page 6-10
Figure 6‐6 on page 6-11
Figure 6‐7 on page 6-12
Figure 6‐8 on page 6-13
Figure 6‐9 on page 6-14
Figure 6‐10 on page 6-15
Figure 6‐11 on page 6-16
Figure 6‐12 on page 6-17
Figure 6‐13 on page 6-18
Figure 6‐14 on page 6-19
Figure 6‐15 on page 6-20
Figure 6‐16 on page 6-21
Figure 6‐17 on page 6-22
Figure 6‐18 on page 6-23
Figure 6‐19 on page 6-24
6-8
Eaton 9395 UPS (450–825 kVA) Installation and Operation Manual
The system oneline drawings in this section show the simplified internal structure of
the UPS, battery supply, and basic maintenance bypass.
UPS Model
Input
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/450
400
9395-825/500
480
9395-825/550
9395-825/450
400
9395-825/500
480
9395-825/550
9395-825/450
400
9395-825/500
480
9395-825/550
9395-825/450
400
9395-825/500
480
9395-825/550
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
9395-825/650
400
9395-825/750
480
9395-825/825
Voltage
Output
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Momentary Static Switch
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Momentary Static Switch
Single Reverse Transfer UPS – Four UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Momentary Static Switch
Single Reverse Transfer UPS – Four UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Momentary Static Switch
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Four UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Four UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Two UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Two UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Common Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
Single Reverse Transfer UPS – Three UPM, Common
400
Rectifier Feed, Separate Battery, Dual‐Feed
480
Configuration, Continuous Static Switch
400
Single Reverse Transfer UPS – Three UPM, Common
480
Rectifier Feed, Common Battery, IOM Configuration
400
Single Reverse Transfer UPS – Three UPM, Common
480
Rectifier Feed, Separate Battery, IOM Configuration
400
Single Reverse Transfer UPS – Four UPM, Common
480
Rectifier Feed, Common Battery, IOM Configuration
S
164201725 Rev 4 www.eaton.com/powerquality
System Type

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plus 1 ups825 ups550 ups9395825/550

Table of Contents