2.6 PLATFORM CONTROL BOX SERVICE
PROCEDURES
Joystick Calibration Procedure
1. Turn off all power to the platform control.
2. Move the joystick to the maximum forward position
and hold it there.
NOTE: Joystick will be held in the maximum forward position
until asked to release it in Step 5.
INTREGRATED
CIRCUIT
BOARD
LOWER
HOUSING
3120728
JOYSTICK ASSEMBLY
S/N- 02996 TO PRESENT
(INCLUDES DRIVE ENABLE BUTTON)
TOUCH PAD
SWITCH
UPPER
HOUSING
Figure 2-14. Platform Control Box Assembly (Exploded View)
SECTION 2 - SERVICE PROCEDURES
3. Turn on power to the platform control, nine (9) LED's
will flash rapidly on the platform control touch pad.
4. Depress the horn switch pad, the alarm will sound
for about one (1) second, then release the horn pad.
5. Now release the joystick to the neutral position.
6. Turn off system power.
The joystick calibration is now complete.
EMERGENCY
STOP SWITCH
– JLG Lift –
JOYSTICK
ASSEMBLY
PRIOR TO
S/N- 02996
(USED THE
TOUCH PAD
ENABLE
SWITCH)
SPEED
CONTROL
KNOB
EMERGENCY
STOP SWITCH
BUTTON
SPEED
CONTROL
SWITCH
2-15