Platform Control - Circuit Board Component Wiring Connections - JLG 10VP Service And Maintenance Manual

Hide thumbs Also See for 10VP:
Table of Contents

Advertisement

3. Remove the four (4) screws attaching the circuit
board to the upper housing.
NOTE: If reusing the circuit board be careful when unsolder-
ing component wires DO NOT OVERHEAT BOARD.
4. Position the circuit board and unsolder the wires
from the joystick assembly at the J2, J3 and J7 loca-
tions on the circuit board. (See Figure 2-15.)
NOTE: (VP model joystick assemblies prior to S/N- 02996
did not have the drive enable button on the joystick
knob. Wires from this design were attached in the J3
location on the circuit board only.)
5. With all the joystick wiring unsoldered remove joy-
stick assembly from the control box.
J2 - J7
JOYSTICK
WIRING
(2 WIRES)
(Later Models With
Enable Button On
Knob Only)
Figure 2-15. Platform Control - Circuit Board Component Wiring Connections.
3120728
J8 - J9
J10 - J11
EMERGENCY
STOP
SWITCH
(4 WIRES)
TOUCHPAD
SWITCH
CONNECTOR
SOCKET
– JLG Lift –
SECTION 2 - SERVICE PROCEDURES
Emergency Stop Switch Removal
1. Remove the switch part of the emergency stop
switch by carefully prying upward at the corner of
the switch using a straight blade screwdriver. This
will seperate the switch from the reset button part of
the emergency stop button assembly.
2. Position the circuit board and locate the emergency
stop switch wires connected at locations J8, J9, J10
and J11. Unsolder the four (4) wires to the switch to
remove the switch from the board. (See Figure 2-15.)
J3
JOYSTICK
WIRING
(5 WIRES)
J5
SPEED
CONTROL
SWITCH
(3 WIRES)
2-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

15vp20vp