Troubleshooting; Troubleshooting Guide - PRG bad boy User Manual

Hide thumbs Also See for bad boy:
Table of Contents

Advertisement

B
B
™ S
L
AD
OY
POT
UMINAIRE

Troubleshooting

Troubleshooting Guide

The following table provides a list of common failures and possible solutions.
Symptom
No power to luminaire.
No console control.
DMX512 control not working
correctly throughout daisy-chain.
Lamp does not strike at power-up.
Comm LED is red indicating that
no valid DMX or Ethernet signal
is detected.
No Ethernet control.
Beam obstructed by gobo in open
position.
Luminaire won't take software
update.
3 8
U
M
SER
ANUAL
Table 4-1: Troubleshooting Guide
Solution(s)
Ensure power cable is properly connected to
Neutrik® input connector.
Ensure power is switched on at source (mains,
disconnect box, etc.)
Ensure DMX512 or Ethernet data cable is
properly connected.
Ensure DMX512 address setting is correct.
Ensure data cables are correctly configured.
Ensure termination connector is installed at last
luminaire in data link.
Configure lamp to start at power-up.
Ensure DMX512 or Ethernet data cable is
properly connected.
Check console.
Ensure that luminaire is not also receiving a
DMX signal. If both valid DMX and Ethernet
control are being received, DMX control will
take precedence.
Set new gobo zero position.
Remove active control (DMX512 or Art-Net).
Refer to...
page 8
n/a
page 15
page 19
page 15
page 10
page 25
page 15
page 18
page 36
page 45
02.9812.0001A

Advertisement

Table of Contents
loading

Table of Contents