Power And Data Cabling Requirements; Power; Data; Dmx512 Cables - PRG bad boy User Manual

Hide thumbs Also See for bad boy:
Table of Contents

Advertisement

B
B
™ S
L
AD
OY
POT
UMINAIRE

Power and Data Cabling Requirements

Power

The Bad Boy™ Spot Luminaire requires standard AC power distribution from 200-240 VAC, 50/60
Hz, 15A maximum. The upper enclosure provides a Neutrik® connector for power input. Use the
provided AC Line Cord Cable Assembly (25.9812.0902.5) to connect power.

Data

DMX512 Cables

The Bad Boy Luminaire is equipped with two, 5-pin XLR connectors for DMX IN and DMX THRU
(out) applications. DMX IN requires a 5-pin, female XLR connector and DMX THRU requires a 5-
pin, male XLR connector. When purchasing or constructing data cables, it is important that not only
the correct cable type be used, but also quality cable to ensure a reliable DMX512 system. Your
cabling should meet the following USITT DMX specification requirements:
Suitable for use with EIA485 (RS485) operation at 250k baud.
Characteristic impedance 85-150 ohms, nominally 120 ohms.
Low capacitance.
Two twisted pairs.
Foil and braid shielded.
24 AWG minimum gauge for runs up to 1000 feet (300m).
22 AWG minimum gauge for runs up to 1640 feet (500m).
Note: Microphone type cables and other general purpose, two-core audio or signal cables are not
suitable for use with DMX512.
8
U
M
SER
ANUAL
LAMP
INFO
125
01:34
hrs
34C
temp
TEST
THRU
1400w
COMM
CONFIG
COMM
043
DMX
addr
A
univ
STATUS
OK
Figure 2-1: Power Input Connector
AC IN
200 -240 VAC
DMX
ETHERNET
50 / 60 Hz
IN
15A Max
Neutrik® AC
Power Connector
02.9812.0001A

Advertisement

Table of Contents
loading

Table of Contents