Connecting Power And Data - PRG bad boy User Manual

Hide thumbs Also See for bad boy:
Table of Contents

Advertisement

Connecting Power and Data

The Bad Boy™ Spot Luminaire may be controlled by DMX512 or Ethernet. The control inputs are
located at the upper enclosure connector panel.
Observe the following guidelines when setting up the system:
The DMX512 Thru port remains active even if the luminaire is not powered up.
A maximum of 32 luminaires may be connected in any one DMX512 or Ethernet data link.
However, note that the maximum limit applies to the luminaire "daisy-chain" only. Your system or
console may require fewer luminaires on a single data link path. Consult your console
documentation for more information.
The Ethernet ports are not assigned as either In or Thru as the DMX512 ports are. Ethernet can be
connected in any configuration.
CAUTION: The Ethernet ports are connected to an internal switch. If power is disconnected to the
luminaire, the switch will go off, therefore cutting communication to downstream luminaires.
Power is provided by the AC Line Cord Cable Assembly (25.9812.0902.5) connected to the Neutrik®
power input connector. There is no power on/off switch.
Note: Refer to
0 2. 9 8 1 2. 0 0 01 A
DMX512 Thru
LAMP
INFO
125
hrs
20:43
34C
temp
TEST
1400W
COMM
CONFIG
COMM
042
DMX
addr
A
univ
STATUS
OK
DMX512 Input
Comm LED
Figure 2-7: Data Connections
"Comm LED Operation" on page 18
I
NSTALLATION
Ethernet Input/Output
AC IN
200 -2 40 VAC
THRU
DMX
ETH ERNET
50 / 60 Hz
IN
15A Max
Ethernet Input/Output
for more details about the Comm LED.
: I
P
NSTALLATION
ROCEDURE
Neutrik® AC
Power Connector
2
15

Advertisement

Table of Contents