Setting the TEMP UPPER alarm

The TEMP UPPER alarm can be
activated when water temperature
increases above the specified value.
Use the TEMP UPPER alarm menu to
specify the temperature upper limit.
The change in water temperature
that can be specifed range from
-10 degC to +50 degC.
The TEMP UPPER alarm setting procedure is shown below.
Display the main menu by pressing the
Move control to "ALARM" by pressing the
then display the ALARM SETTING submenu by pressing the
key.
Move control to "TEMP UPPER" by pressing the
and then display the TEMP UPPER ALARM submenu by
pressing the
Move control to "FUNCTION" by pressing the
then select "ON" by pressing the
Move control to "UPPER LIMIT" by pressing the
and then specify the desired alarm activation water temperature
value by pressing the
Example: 20.0 degC. (for activating the alarm when water
temperature increases above 20.0 degC.)
Press the
Press the
Setting the TEMP LOWER alarm
The TEMP LOWER alarm can be
activated when water temperature
decreases below the specified value.
Use the TEMP LOWER alarm menu to
specify the temperature lower limit.
The change in water temperature
that can be specifed range from
-10 degC to +50 degC.
The TEMP LOWER alarm setting procedure is shown below.
Display the main menu by pressing the
Move control to "ALARM" by pressing the
then display the ALARM SETTING submenu by pressing the
key.
Move control to "TEMP LOWER" by pressing the
and then display the TEMP LOWER ALARM submenu by
pressing the
Move control to "FUNCTION" by pressing the
then select "ON" by pressing the
Move control to "LOWER LIMIT" by pressing the
and then specify the desired alarm activation water temperature
value by pressing the
Example: 17.0 degC. (for activating the alarm when water
temperature decreases below 17.0 degC.)
Press the
Press the
40 3.OPERATIONS
key.
or
key.
key to return to the ALARM MENU.
MARK
key to return to the fishfinding display.
GRAPH
key.
or
key.
key to return to the ALARM MENU.
MARK
key to return to the fishfinding display.
GRAPH
Alarm
Water temp. upper limit value
Changes
in water temperature
and
keys together.
or
key, and
or
key,
or
key, and
or
key.
or
key,
Water temp. lower limit value
Alarm
Changes
in water temperature
and
keys together.
or
key, and
or
key,
or
key, and
or
key.
or
key,
Main menu
ALARM
TEMP UPPER
TEMP UPPER ALARM
FUNCTION "ON"
ALARM
TEMP LOWER
TEMP LOWER ALARM
FUNCTION "ON"
ALARM

Advertisement

Table of Contents
loading

Table of Contents