Control Fuses; Under- And Overvoltages In The Mains Supply; Loss Of A Phase In The Mains Supply; Disposal Of The Machine - Kemppi KMS 300 Operating Manual

Hide thumbs Also See for KMS 300:
Table of Contents

Advertisement

6.2

CONTROL FUSES

Fuse F11, 6.3 A delayed, on the rear wall of machine is as protection for connection of auxiliary
devices X14-15.
Use same type and rating of fuse which is marked beside the fuse adapter. Damage caused
NOTE!
by a wrong type fuse is not covered by the guarantee.
6.3

UNDER- AND OVERVOLTAGES IN THE MAINS SUPPLY

Primary circuits of machine are protected against sudden, transient overvoltages.
Machine is designed to withstand 3 x 440 V voltage continuously (see technical data). See to
it that voltage is kept within admissible limits especially when mains supply is taken e.g. from
combustion engine generator.
If the mains has undervoltage (under approx. 300 V) or overvoltage (over approx. 480 V)
machine control stops to operate automatically.
6.4

LOSS OF A PHASE IN THE MAINS SUPPLY

Loss of a phase causes noticeable poorer welding properties than normally or the machine
doesn't get started at all. Loss of a phase can be due to following:
• blowing of mains supply fuse
• defective mains cable
• bad connection of mains connection cable on terminal block or plug of machine
7.

DISPOSAL OF THE MACHINE

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and taken to an appropriate
environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional
collection centre, per the instructions of local authorities or a Kemppi representative. By
applying this European Directive you will improve the environment and human health.
EN