Signamax™ ™ ™ ™ Gigabit SFP Hardened Media Converter
Installation
This chapter gives step-by-step installation instructions for
the Converter.
Selecting a Site for the Equipment
As with any electric device, you should place the equipment
where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the
site you select should meet the following requirements:
The ambient temperature should be between - 40 to 167
degrees Fahrenheit (- 40 to 75 degrees Celsius).
The relative humidity should be less than 95 percent,
non-condensing.
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
Make sure that the equipment receives adequate ventilation.
Do not block the ventilation holes of the equipment.
The power outlet should be within 6 feet (1.8 meters) of the
product.
Wiring Diagram
Field Wiring Terminal Markings: Use Copper Conductors
Only, 140/167℉ (60/75℃), wire range 12-24 AWG, torque
value 7 lb-in.
User's Manual
9