Do not maintain the equipment alone when it is energized, unless absolutely necessary.
Be sure to make a careful check before you shut down the power supply.
Do not pl ace t he e quipment i n a d amp/wet location. D o no t l et an y liquid e nter t he
chassis
Connect the negative and positive lines correctly according to the instructions when DC
power supply is used.
All grounding conductors should be connected before and disconnected after the line
and neutral(AC)/ input(DC) c onductors.
Warning
Warning
2.1.4

Static Discharge Damage Prevention

Although m uch has been done in t he DES-7210/7206 to pr event s tatic el ectricity, gr eat
damage may be caused to the circuitry and equipment when the static electricity exceeds a
certain limit.
In the communication network of the DES-7210/7206, electrostatic induction may come from
the following sources:
External electric field produced by the high-voltage supply cable, lightning, etc;
Internal systems such as the indoor floor and the entire structure.
To prevent damage from static electricity, you must pay attention to the following:
1.
Proper grounding of the equipment and floor
2.
Dust prevention measures are taken in the room.
3.
An appropriate humidity is maintained.
4.
Always wear an anti-static wrist strap when you touch any circuit board.
5.
Try to hold a circuit board by its edges. Do not touch any components or the PCB.
6.
Do not let any clothes touch a circuit board. An antistatic wrist strap can only prevent
static electricity from human damaging the circuit board, but cannot prevent any static
electricity on clothes.
- Min. 1 0mm² ( 6AWG) pr otective grounding conductor s hould be pr ovided t o t he
equipment grounding terminals on rear panel.
- For po wer s upply unit 7200-2000DC, m in. 1 0mm² ( 6AWG) pr otective grounding
conductor should be provided to input terminal;
- For po wer s upply unit 7200-1200DC, m in. 4m m² ( 10AWG) pr otective grounding
conductor should be provided to input terminal;
- For po wer s upply unit 7 200-2000AC and 72 00-1200AC, m in. 2. 5mm² ( 12AWG)
protective grounding conductor should be provided to input terminal.
Any nonstandard a nd i naccurate electrical op eration c an cause an
accident s uch as f ire or el ectrical at tack, t hus causing s evere e ven f atal
damages to human bodies and equipment.
Direct or i ndirect t ouch t hrough a wet o bject on h igh-voltage a nd m ains
supply can bring a fatal danger.