Backup Recording

Backup Recording of this Device's Cam-
era
Image
and
Sound
IEEE1394 Connector
This device's camera image and sound can be recorded for
backup on another component that is equipped with
IEEE1394 connector.
Connections
Use this device as the master unit.
Connect the master unit and the backup unit with a
IEEE1394 cable.
1.
IEEE1394 switch
Master unit
(this device)
Settings
Master unit (this device)
1.
Set the IEEE1394 switch on left side of this device.
DV
: When backup in DV format
HDV : When backup in HDV format
2.
Place in Camera mode.
3.
Set the 1394 REC TRIG. item on the OTHERS[2/2] menu
screen. X See page 94.
For HDV mode, set the BACK SPACE [HDV] item.
X See page 94.
OTHERS[2/2] menu screen
Through
the
Backup unit
IEEE1394 cable
Signal flow
Backup unit
• Place in HDV/DV signal input mode.
* Depending on the used component, it may be neces-
sary to set "REMOTE SELECT".
• When BR-HD50 is used, set the Backup Recording
function to OFF.
Also, set REM SEL HDV/DV in the REMOTE[1/2] menu
of the BR-HD50 to ON or LOC+REM.
• Insert the tape and set to STOP or REC PAUSE status.
CAUTION
• Set the IEEE1394 switch on both devices to either HDV
or DV.
• Start recording after making sure that both devices are
properly connected.
• If the RET button is pressed during backup recording,
output from the IEEE1394 terminal is stopped, the image
is switched to the image recorded on this device, inter-
rupting the backup recording image.
Operation
Start and stop of recording on the backup unit takes place in
accordance with the operation of the REC/VTR trigger button
on the master unit.
(Depending on this device or the backup unit, the image,
audio, and/or time code may deviate from what they should
be at the points where the recording is started or stopped.)
MEMO
• When the backup recording is started, the "TRIGGER
TO DV" or "TRIGGER TO HDV" indication is shown on
the LCD or in the viewfinder for approx. 3 seconds.
• When the Series Recording function of BR-HD50 is
used, this device's 1394 REC TRIG. item should be set
to OFF.
• If the backup device is equipped with a feature to record
time codes input from the IEEE1394 connector (TC
DUPLICATE feature), time code data the same as on the
master side can be recorded.
If the master unit tape is paused or stopped when the
master unit time code running mode is in REC RUN
mode, the time code for the slave unit stops.
• When using BR-HD50 as a backup device and switching
this device from the playback mode to the record mode,
noise will be noticed on the monitor output screen of BR-
HD50 (backup will be correctly recorded).
• In 1080I CAMERA mode, signal cannot be recorded into
tape.